Installation of molded brick panel, A. install hearth molded brick panel, B. install back molded brick panel – Hearth and Home Technologies CASTLEWOOD 42 User Manual
Page 19: C. install side molded brick panel

Outdoor Lifestyles by Hearth & Home Technologies Inc. • 4070-300 Rev D • 11/11
19
7
Installation of Molded Brick Panel
A. Install Hearth Molded Brick Panel
1. Put a level on fireplace to verify it is level side to side
and front to back.
2. While the hearth is removed from the fireplace , measure
all 4 corrners to determine the variance from corner to
corner. See Figure 7.1.
3. Shim the low corners of the hearth refractory by installing
the metal pieces provided on the fireplace bottom. See
Figure 7.2.
4. Put a level on the top flange of the refractory and shim as
necessary from side to side or front to back. See Figure
7.3.
Note: The top flange of the hearth should be level to allow
the sides and back to be installed with minimal gaps. The
hearth slopes towards the front of the unit approximately
1/4”.
B. Install Back Molded Brick Panel
•
Refer to Figure 7.4.
•
Set the grate retainer in place, in the notch in the
hearth.
•
Install the back panel. Center from side to side.
•
Install rear refractory retainer.
Figure 7.1.
Figure 7.2.
Figure 7.3.
C. Install Side Molded Brick Panel
• Remove screen rods.
• Remove smoke shield
• Install side panel by lifting up, setting on top flange of
hearth and slide towards back of unit until it meets up
with back panel.
• Install refractory retainer
• Install second side panel following the steps above.
Replace the smoke shield.
• Install refractory retainer.
Side Refractory Retainer
Back Refractory Retainer
Back Molded Brick Panel
Grate Retainer
Hearth Retainer
Side Refractory Retainer
Right Side Molded Brick Panel
Left Side Molded Brick Panel
Gas tube locator dimple
Figure 7.4