8) Move the control switch to the "OFF" position. Remove the upper front, top and left side

panels.

9) Move the power switch to the "OFF" postion. Unplug the icemaker from the electrical

outlet.

10) Disconnect the ice transport hose from the spout, and pour fresh water into the ice

transport hose to rinse out the solution and fill the evaporator and reservoir. Be careful
not to overfill the reservoir. Reconnect the transport hose.

11) Plug the icemaker back in. Move the power switch to the "ON" position and replace the

panels in their correct positions.

12) Move the control switch to the "ICE" position. Run the icemaker until it stops

automatically.

13) Move the control switch to the "DRAIN" position, and wait about 15 minutes for the

water system to drain.

14) After the water has drained, move the control switch to the "OFF" position. Remove the

upper front, top and left side panels.

15) Move the power switch to the "OFF" position. Unplug the icemaker from the electrical

outlet.

16) Open the water supply line shut-off valve. Check for water leaks.
17) Plug the icemaker back in. Move the power switch to the "ON" position and replace the

panels in their correct positions.

18) Move the control switch to the "ICE" position and run the icemaker about 30 minutes.
19) Move the control switch to the "OFF" position.
20) Activate the dispense sensor to remove the ice from the storage bin. Remove the upper

front, top and left side panels.

21) Move the power switch to the "OFF" position. Unplug the icemaker from the electrical

outlet.

22) Remove the front cover of the storage bin. Pour warm water into the storage bin to melt

any remaining ice.

23) Clean the storage bin with water.

WARNING

Do not use ice produced from the cleaning and sanitizing solution. Be sure no
ice remains in the storage bin.

24) Replace the front cover of the storage bin, then plug the icemaker back in. Move the

power switch to the "ON" position and replace the panels in their correct positions.

25) Move the control switch to the "DRAIN" position, and wait about 15 minutes for the

water system to drain.
Note: If cleaning the dispensing components, proceed to "B. Cleaning and Sanitizing

Instructions - Dispensing Components."

26) After the water has drained, move the control switch to the "ICE" position to start the

automatic icemaking process.