beautypg.com

Electrical connection – Hoshizaki KM-1301SWH/3 User Manual

Page 22

background image

22

5. Electrical Connection

WARNING

1. Electrical connections must meet national, state, and local electrical code

requirements. Failure to meet these code requirements could cause severe
injury to individuals or extensive damage to equipment.

2. Be sure to install a proper ground from the icemaker to the remote condenser

unit.

3. To reduce the risk of electric shock, do not connect the power supply until

after all condenser unit connections have been made.

4. On remote air-cooled model, the icemaker should have power for a minimum

of 4 hours prior to startup to prevent compressor damage.

• This remote condenser unit must be connected to the fan motor junction box on the

icemaker.

• Usually an electrical permit and services of a licensed electrician are required.
• Power supply and ground wire to the condenser unit are supplied from the icemaker.

Connect the condenser unit and icemaker using appropriate outdoor-rated wire.

1) Remove the louver panel. See Fig. 12.
2) Remove the junction box cover on the remote condenser unit. Remove the fan motor

junction box cover on the icemaker.

3) Install a ground wire from the icemaker to the remote condenser unit.
4) Connect the fan motor leads in the junction box of the remote condenser unit to the fan

motor leads in the fan motor junction box of the icemaker.

5) Replace the junction box covers and the louver panel in their correct positions.

Fig. 12

Screws

Junction Box Cover

Louver Panel

Screws