Hoshizaki KM-260BAH User Manual
Page 37
32
[d] KM-260BWH
10sec
10sec
10sec
10sec
10sec
10sec
10sec
10sec
10sec
10sec
HARVEST CYCLE
Thermistor senses 9°C
after 6 min to 8 min 50 sec
in harvest cycle (Ver 3.1 or
later)
6min
3min
10sec
6min
60sec
PART NAME
FREEZE CYCLE
HARVEST CYCLE
(INCLUDING DRAIN)
FREEZE CYCLE
HOT GAS VALVE
WATER VALVE
ON
OFF
CLEANING VALVE
HARVEST CYCLE
(AFTER BIN FULL)
BIN FULL
HARVEST CYCLE
OFF
DRAIN VALVE
ON
ON
OFF
ON
OFF
ON
RELAY: X3
(PM)
OFF
ON
OFF
ON
RELAY: X4
(WV)
FLOAT SWITCH
ON
OFF
BIN CONTROL
SWITCH
ON
OFF
OFF
ON
OFF
CONT
ROL B
OA
RD
RELAY: X6
(DV)
RELAY: X1
(COMP)
RELAY: X2
(HV/FM)
FAN MOTOR
ON
OFF
ON
Program Ver 2.5
or earlier
(Auxiliary Code:
V-0 or earlier
)
ON
OFF
PU
MP MO
TOR
Program Ver 3.2
or later
(Auxiliary Code:
V-1 or later
)
OFF
FREEZE CYCLE
HARVEST CYCLE
Thermistor senses 9°C after more than
8 min 50 sec in harvest cycle (Ver 3.1
or later)
ON
HARVEST CYCLE
FREEZE CYCLE
HARVEST CYCLE
(INITIAL)
OFF
ON
OFF
9°C
5°C
POWER SWITCH
THERMISTOR
ON
OFF
1°C
COMPRESSOR
Max 6 min
5 sec
Max 6 min
Max 6 min
10 sec
Max 6 min
15 sec
10 sec
90 sec
Max 6 min
10 sec
10 sec
10 sec
10 sec OFF, 50 sec ON
10 sec OFF, 50 sec ON
10 sec OFF, 50 sec ON
10°C
10°C
10°C
Max 6 minMax 6 min
10 sec
10 sec OFF, 50 sec ON
10°C
Max 6 min
Max 6 min