beautypg.com

Sr2122-2 configuration rules, Sr2122-2 router rules, Table 1: sr2122-2 router rules – HP SR2122-2 User Manual

Page 9: Iscsi host rules, Table 2: iscsi host rules, Operation system rules, Iscsi host rules operation system rules

background image

SR2122-2 configuration rules

9

SR2122-2 IP Storage Router Release Notes

SR2122-2 configuration rules

SR2122-2 router rules

The SR2122’s 2

nd

fibre Channel port (FC2) is not supported as a redundant SAN port for

FC1.

Direct connect of the SR2122-2 Fibre Channel ports to any HP storage array is not
supported.

The MSR2122 Management port must be in a different subnet than the SCSI Router
Instances.

iSCSI host rules

Operation system rules

Linux Clustering is not supported.

HP Secure Path for Linux with the MSA1000, RA/MA8000, EMA/ESA12000 and
Enterprise Virtual Arrays is not supported.

HP Auto Path for VA/XP for HP-UX, Windows 2000, Windows 2003 and Linux are not
supported.

HP Secure Manager on XP and VA is not supported.

The MSA1000 is not supported with Secure Path for Windows

Table 1: SR2122-2 Router Rules

Router Rule

Maximum

Maximum scsirouter instances per SR2122-2 Router

(and per SR2122-2 Router Cluster)

12

Maximum iSCSI host connections per

SR2122-2 SCSI Router instance

32

Maximum active logical units (LUNs) per SR2122-2 Router

120

Maximum active targets per SR2212-2 Router

120

Table 2: ISCSI Host Rules

iSCSI Host Rule

Operating System

Maximum

Maximum targets accessed per iSCSI host

Windows 2000,

Windows 2003, HP-UX, Linux

120

Maximum active LUNs per target

Windows 2000,

Windows 2003, Linux, HP-UX

120