beautypg.com

Web client operation – Honeywell HD-DVR-1016 User Manual

Page 150

background image

Web Client Operation

136

Parameter

Function

Event Type

There are three types: Motion detection/video loss/Camera
Masking.

Channel

Select channel name from the dropdown list, and check the
checkbox beside it to enable its motion detection function.

Sensitivity

There are six levels. The sixth level has the highest
sensitivity.

Region

There are six levels. The sixth level has the highest
sensitivity.

Region: If you select motion detection type, you can click this
button to set motion detection zone. The interface is shown in

Figure 6-40

. There are PAL 22X18/NTSC 22X15 zones.

Right-click and you can go to the full-screen display mode. Do
remember to click OK to save your motion detection zone
setup.

Period

Motion detection function becomes activated in the specified
periods.

There are six periods in one day. Please check the checkbox
to enable corresponding period.

Select date. If you do not, the current setup applies to today
only. You can select all week column to apply to the whole
week.

Click OK, and the system goes back to motion detection
interface; please click Save to exit.

Anti-dither

Not Effective in the current DVR version.

Alarm out

There is 3-channel alarm output.

Corresponding to motion detection alarm output port (multiple
choices)

Enable alarm activation function. You need to select alarm
output port so that the system can activate the corresponding
alarm device when an alarm occurs.

Alarm latch

System can delay the alarm output for a specified time after a
detection event ends. The value ranges from 10s to 300s.

Record
channel

System auto activates motion detection channel (multiple
choices) to record once alarm occurs (working with motion
detection function). Please note you need to go to the chapter

Motion Detection

to set motion detection record period and go

to the chapter

Manual Record

to set the current period as

auto record.

Record latch

System can delay the record for specified time after a
detection event ended. The value ranges from 10s to 300s.

Email

If you enabled this function, the system can send out email to

This manual is related to the following products: