Taking care of unexpected problems – HONDA Outboard Motor BF135A User Manual
Page 93
10 A, 15 A, 30A
91
Replacement
TAKING CARE OF UNEXPECTED PROBLEMS
FUSE CASE LID
FUSE PULLER
‘‘90A’’MARK
FUSE (90A)
SPARE FUSE (90A)
ACG Fuse
Disconnect the battery cable at the
battery negative (-) terminal bef ore
replacing the f use.
Failure to do so may cause a short
circuit.
Never use a f use with a rating
greater than specif ied. Serious
damage to the electrical system could
result.
Remove the engine cover.
Stop the engine.
If a blown fuse is found, try to
determine and correct the electrical
problem that caused the blown fuse.
An uncorrected electrical problem
may cause the fuse to blow again.
If fuses continue to blow, take the
outboard motor to an authorized
Honda marine dealer for inspection
and service or refer to the shop
manual.
Use the fuse puller from the tool
kit to remove the fuses. If a fuse is
blown, install a replacement fuse
of the same specified rating. The
outboard motor is supplied with
spare fuses in the fuse holder.
MAIN FUSE RATINGS:
Reinstall the fuse cover and the
engine cover.
1.
2.
4.
3.
04/01/21 11:23:47 31ZY6600_092