beautypg.com

Technical specifications, Quickspecs – HP COMPAQ 6005 User Manual

Page 15

background image

Unit Environment and Operating
Conditions

Microtower

Small Form Factor

General Unit Operating Guidelines

Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that
unit is operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each
other's re-circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other
foreign matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the
enclosure, and the same operating guidelines listed above will still apply.

Temperature Range

Operating: 50° to 95° F (10° to 35° C)

*

Non-operating: -22° to 140° F(-30° to 60° C)

Relative Humidity

Operating: 10% to 90% (non-condensing at ambient)

Non-operating: 5% to 95% (non-condensing at ambient)

Maximum Altitude (unpressurized)

Operating: 10,000 ft (3048 m)

Non-operating: 30,000 ft (9144 m)

* Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained
sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options
installed.

Microtower

Small Form Factor

Power Supply

320-watt BTX power

supply - Active PFC

320-watt 89%

efficient

*

BTX power

supply - Active PFC

240-watt BTX power

supply - Active PFC

240-watt 89%

efficient

*

BTX power

supply - Active PFC

Operating Voltage Range

100-240VAC

100-240VAC

100-240VAC

100-240VAC

Rated Voltage Range

115V/230V

115V/230V

115V/230V

115V/230V

Rated Line Frequency

50/60 Hz

50/60 Hz

50/60 Hz

50/60 Hz

Operating Line Frequency Range

47-63 Hz

47-63 Hz

47-63 Hz

47-63 Hz

Rated Input Current

5.5A

5.5A

4A

4A

Heat Dissipation (NEED TO
UPDATE)

Typical 315 btu/hr

(79 kg-cal/hr)

Maximum 1575 btu/hr

(397 kg-cal/hr)

Typical 270 btu/hr

(68 kg-cal/hr)

Maximum 1280 btu/hr

(322 kg-cal/hr)

Typical 315 btu/hr

(79 kg-cal/hr)

Maximum

1260 btu/hr

(317 kg-cal/hr)

Typical 270 btu/hr

(68 kg-cal/hr)

Maximum 1025 btu/hr

(258 kg-cal/hr)

Power Supply Fan

Variable speed fan

Variable speed fan

Variable speed fan

Variable speed fan

ENERGY STAR Compliant

X

X

FEMP Standby Power Compliant
(<1W in S5 - Power Off)

**

X

X

X

X

Power Consumption in ENERGY
STAR Mode - Suspend to RAM
(S3)
(Instantly Available PC)

<2.4W

<2.4W

<2.4W

<2.4W

* Energy efficient power supply is a requirement for ENERGY STAR qualification in conjunction with a select range of
processors and modules
** Power consumption in the Off/Apparent Off mode is measured and reported with the network interface controller "Wake
on LAN" feature disabled in F10 Setup (default is "enabled").

QuickSpecs

HP Compaq 6005 Pro Business PC

Technical Specifications

DA - 13412 Worldwide QuickSpecs — Version 6 — 10/14/2009

Page 15