beautypg.com

Heath Zenith SL-5525 User Manual

Motion sensing halogen fixture, Operation, Model sl-5525

background image

© 2004 DESA Specialty Products™

595-5295-11

1 Halogen

Lamp

Sensor

Light Control

Requirements

• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be

wired through a switch.

• Some codes require installation by a qualified

electrician.

• This product is intended for use with the enclosed

gasket and with a junction box marked for use in wet
locations.

Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).

Motion Sensing
Halogen Fixture

Model SL-5525

3 Wire

Connectors

6 Screws

(3 sizes included)

Gasket

Mounting Bolt

Mounting Strap

OPERATION

* resets to Auto Mode at dawn.

MANUAL MODE

ON-TIME

10 5 1 TEST

10 5 1 TEST

ON-TIME

TEST

... back on.

AUTO

1 Second OFF

then...

Move ON-TIME Switch to

1, 5, or 10 minutes

Mode Switch Summary

Flip light switch off

for one second

then back on*

MANUAL MODE

AUTO

TEST

* If you get confused while switching modes, turn the

power off for one minute, then back on. After the
calibration time the control will be in the AUTO mode.

Note: When first turned on wait about 1

1

/

2

minutes for

the circuitry to calibrate.

Light Shield

Plastic Hanger

Rubber Plug

Mode:

On-Time:

Works:

Day

Night

Test

5 Sec

x

x

Auto

1, 5, 10 min.

x

Manual

Until Dawn*

x

Put the ON-TIME switch on the bottom
of the sensor in the TEST position.

Put the ON-TIME switch in the 1, 5,
or 10 minute position.

Manual mode only works at night
because daylight returns the sen-
sor to AUTO.

Flip the light switch off for one sec-
ond then back on to toggle between
AUTO and MANUAL MODE.

Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.

This package includes: