Model MP-941/942/943/944



2-2. UNPACKING (Continued)

4. Open drawers and remove the packing or literature

that is inside.

5. Pull off any protective covering from the exterior of

the

cabinet.

6. Your multipurpose holding cabinet is now ready

for location and setup.

2-3. ELECTRICAL

The multipurpose holding cabinets are available from

the factory as 120 VAC for domestic use, or 230 VAC

for international use. The units are single phase and

require a grounded (earthed) receptacle with a separate

electrical line protected by a fuse or circuit breaker of

the proper rating.

The electrical plugs for the 230 volt units must be

supplied by the distributor and have the proper

DATA TABLE:

grounding (earthing).

To avoid electrical shock, the cabinet must be

adequately and safely grounded (earthed)

according to local electrical codes.


(FOR EQUIPMENT WITH CE MARK ONLY!)

To prevent electric shock hazard this appliance

must be bonded to other appliances or touchable

metal surfaces in close proximity to this

appliance with an equipotential bonding

conductor. This appliance is equipped with an

equipotential lug for this purpose. The

equipotential lug is marked with the following

symbol

After the multipurpose holding cabinet has been set into

position and leveled, run a bead of silicone rubber

(silicone or equivalent sealant must be a NSF listed

material) around the perimeter of the unit sealing it to

the surface. You are now ready to make the electrical

connections to the unit.





2-2

208

Model

Number

Volts

Phase

Watts

Amps

MP-941 120 1 475 3
MP-942 120 1 950 6
MP-943 120 1 1425 9
MP-944 120 1 1900 12
MP-941 230 1 475 2
MP-942 230 1 950 4
MP-943 230 1 1425 6
MP-944 230 1 1900 8