beautypg.com

Henny Penny MP-944 User Manual

Page 15

background image

Model MP-941/942/943/944



3-6. OPERATION AND

Setting Control to the Correct Number of Drawers

PROGRAMMING

(Continued)

The different models, MP-941, 942, 943, and 944, all use

the same control board. The boards are programmed at

the factory for the correct unit. But, should the unit show

“E06” or some drawers will not heat, the board may not

be

programmed

for

the

appropriate

unit.

The LED flashes at a fast rate for the drawer(s) not

programmed correctly.

To check the drawer programming, turn the unit off, then

back on. The display will flash the number of drawers

the unit is programmed for. If the unit is not programmed

correctly, follow these steps:

1. Turn the power switch off, then press and hold the

SET button and the drawer button, which corresponds

to

the

number

of

drawers that the unit has, and turn

unit back on, ex: MP-944=SET and number 4 button.

2.

Release

the

buttons, and now the unit should be set

up

for

use.

Pressing and holding the drawer button shows the

temperature of that drawer. If no temperature is

displayed, the unit may need to be programmed by

the

above

steps.

3-7. ERROR CODES

DISPLAY

CAUSE PANEL

BOARD

CORRECTION

E-4”

Control board

Turn switch to OFF position, then turn switch back to

overheating

ON; if display shows “E-4,” the control board is

getting too hot; make sure unit is not overheating

“E-6”

Faulty temperature

Check to see if unit is set to the correct number of

probe

drawers, ex: MP-942=2 drawers (see programming

instructions)

“E-41”

Memory scrambled Press and release the UP and DOWN buttons to

initialize the program; if “E-41” persists replace the

control

board

“Hi”

Unit overheating;

Have relay or control board replaced

faulty

relay

or

con

trol

board


3-6

203