beautypg.com

5. engine prestart checks – Hobart Welding Products CHAMPION 4500 User Manual

Page 22

background image

OM-4418 Page 18

Open/On

1

Closed/Off

5-5. Engine Prestart Checks

803 468-D

Full

Gasoline

1/2 in

(13 mm)

Check all fluids daily. Engine must

be cold and on a level surface. Unit

is shipped with 10W30 engine oil.
Engine stops if oil level gets too low.
1

Fuel Valve

Open valve.

.

Close fuel valve before moving
unit or carburetor may flood

and make starting difficult.

Fuel
Add fresh fuel before starting

engine the first time . Fill fuel tank up

to 1/2 in. (13 mm) from top to allow

room for expansion. Check fuel lev-

el on a cold engine before use each

day.
Oil
After fueling, check oil with unit on

level surface. If oil reservoir is not

full, add oil until oil nearly overflows

at oil fill.

.

This unit has a low oil level

shutdown switch to prevent

starting an engine that is low on

oil. However, some conditions

may cause engine damage be-

fore the engine shuts down.

Check oil level often and do not

use the low oil level shutdown

system to monitor oil level.

.

To improve cold weather start-

ing, use correct grade oil for

cold weather (see engine own-

er’s manual).

.

Always close fuel valve after
stopping unit. Moving unit

with fuel valve open may

cause carburetor flooding

and make starting difficult.