beautypg.com

4. duty cycle, 5. generator power curve, Ac power v olts ac power amperes – Hobart Welding Products CHAMPION 4500 User Manual

Page 18

background image

OM-4418 Page 14

4-4. Duty Cycle

212 950

Duty cycle is the percentage of 10

minutes that unit can weld at rated

load without overheating.
1

100% Duty Cycle

This unit is rated for continuous

welding at 90 amperes CC/AC.
2

30% Duty Cycle

This unit is rated at 30% duty cycle

(3 minutes welding, 7 minutes rest-

ing) at 140 amperes CC/AC.
NOTICE − Exceeding duty cycle

can damage unit and void warranty.

1

2

4-5. Generator Power Curve

226 077

The ac generator power curves

show the generator power available

in amperes at the receptacles.

300

250

200

150

100

50

0

0

10

20

30

40

50

60

AC Power V

olts

AC Power Amperes