HP MSL6000 Series User Manual
Page 105

MSL6000 series tape library user guide 105
1005
Illegal SCSI Cnt Cmd
(Either an invalid command was sent to
the SCSI controller, or the controller was
not in the correct mode.)
•
Turn off power to the library and inspect
connectors and cables.
•
Check that application is certified to work
with your library and has up-to-date
patches.
•
Ensure SCSI options are set correctly.
•
Check the SCSI cable connections to
make sure they are secured.
•
Make sure the library controller board
has SCSI termination.
•
Check host SCSI cable and connections.
1007
SCSI Invalid Element
(Internal SCSI task processing error.
Invalid element type was detected.)
•
Turn off power to the library and inspect
connectors and cables.
•
Check host SCSI cable and connections.
1008
SCSI No Pending Int.
•
Turn off power to the library and inspect
connectors and cables.
1009
SCSI Invalid Int.
(The SCSI controller posted an invalid
interrupt status.)
•
Turn off power to the library and inspect
connectors and cables.
•
Check host SCSI cable and connections.
100F SCSI Un-terminated Resets
(SCSI Continuous Resets Detected)
•
Verify that the library SCSI bus is
properly terminated.
• Update the Map using the LCD touch
display. (Menu -> Maintenance -> Force
reconfiguration)
2004
Loader Not Ready
(Failed to fetch, stow, scan, move, pass
through, or loader detected invalid
command and aborted.)
•
Cycle power to the library or reboot
using the GUI touch screen.
2008
Illegal Move
•
Verify the source and destination of the
move operation.
• Update the Map using the LCD touch
display. (Menu -> Maintenance -> Force
reconfiguration)
2009
Door Open (status only)
(Door is forced open or door sensor
failed.)
•
Invalid user initiated operation. Select
parameters correctly and try again.
•
Make sure door(s) are closed.
•
Press the Enter button to clear the
message.
Table 10
Fault Symptom Codes (continued)
FSC
Message
ERP