beautypg.com

Caution – Hearth and Home Technologies GO24-IPI-LP User Manual

Page 9

background image

Hearth & Home Technologies • Grand Oak Gas Log Sets • 4004-299 Rev H • 05/08

9

L. Inspect the Venting System

The fireplace venting system is designed and constructed to

develop a positive flow adequate to remove flue gases to the

outside atmosphere. See fireplace installation instructions.

Possible cures if spilling occurs:

• The damper needs to be opened further.

• The fireplace opening needs to be reduced by adding a

drop panel across the top under the lintel.

• The air supply from outdoors needs to be increased. Open

the outside air kit if the appliance is so equipped, or crack

open a door or window.

• If necessary, seek expert advice. Do not operate this

appliance.

Cleaning

• Periodic examination and cleaning of the venting system

of the fireplace should be done before initial use and at

least annually by a qualified agency.

A spillage test must be made before the installed

appliance is left with the consumer.

• Close all doors and windows in the home.

• Light the log set (see Lighting Instructions).

• After three minutes, test with a smoke match, smoke

candle, stick incense or cigarette in. below the top of

the opening (lintel) moving across the full width. If spillage

(smoke down into the room) occurs, it will most likely be

near the top, outside corners.

Before cleaning the appliance, be sure it is turned

completely off. The pilot should also be turned off. The

unit must be completely cooled.

CAUTION

• Logs can get very hot. Handle only when they are

cool.

CAUTION

After burning, the logs become fragile. Take care in

handling.

CAUTION

M. Cleaning and Maintenance Instructions

Always remember:

• Do not place any combustible material near the

appliance.

• Do not place any paper, trash or other material on the log

set or in the fireplace.

• Do not touch any part of the appliance when it is in

operation.

• Do not operate this appliance without the fireplace screen

closed.

Your appliance is designed to be virtually maintenance free,

although periodic visual inspection and cleaning is required.

Follow the instructions below for the correct procedures. An

annual examination and cleaning the venting system by a

qualified person is also recommended.

N. Safety Valve Pilot Flame Adjustment In-

structions

The pilot flame adjustment screw is located on the front

side of the pilot gas tubing port. Using a small straight blade

screwdriver, turn the screw clockwise to adjust the pilot

flame down and counterclockwise to adjust the flame up.

This screw is sensitive; therefore it will not take much adjust-

ment to accomplish this flame adjustment.

PILOT

ON

OFF

Pilot

Thermocouple

Do not allow soot to build up on the logs

Your logs require little care. Keep the burner assembly, logs

and burner area surrounding the logs clean by brushing with

a dry paint brush at least twice a year.

• Always turn off the gas to the pilot before cleaning.

For relighting, refer to Section P Thru R. Lighting

Instructions.

• Always keep the appliance clean and free from combustible

materials, gasoline and other flammable vapors and

liquids.

• Never obstruct the flow of combustion and ventilation air.

Keep the front of the appliance clear of all obstacles and

materials.

• Leave clearance of at least 6 in. from the front of the

fireplace.