beautypg.com

Warning – Hearth and Home Technologies GO24-IPI-LP User Manual

Page 8

background image

Hearth & Home Technologies • Grand Oak Gas Log Sets • 4004-299 Rev H • 05/08

8

Damper

Stop Clamp

Damper

Figure 8

Damper Stop Clamp

K. Damper Stop Installation Instructions

Included in the burner assembly box is a damper stop clamp

which attaches to the damper as shown (Figure 8). Install

the clamp to the damper ensuring that the minimum require-

ments (Tables and 2) are achieved. Use a 7/6 in. wrench

to secure the clamp to the damper. If the damper clamp pro-

vided does not fit your application, other means of securing

the proper opening must be provided by the installer.

Inspect the pilot burner to ensure it is clear of any

rock wool.

• Remove the Platinum Bright Embers™ from the package.

For optimum performance peel each piece apart in layers

and lightly place on top of the vermiculite and rock wool

where the flame is blue. This will achieve the desired

realism.

• The gas burns at the point of the least resistance. In

case of an uneven flame pattern it may be necessary to

adjust the materials in the pans (using an object such as

a screwdriver) to achieve the desired effect.

• Place desired amount of lava granules on the floor of the

fireplace. DO NOT ALLOW THE GRANULES TO COME

IN CONTACT WITH THE FLAMES. (Lava granules may

contain moisture which, when heating, may cause it to pop

out during installation and set-up.) Ensure that the controls

and switches are unobstructed after the granules are

installed. DO NOT COVER THE AIR MIXER LOCATED

ON THE LOWER LEFT SIDE OF THE BURNER.

• Place logs as shown in Sections S thru Z.

• Place accent logs around burner on floor of fireplace.

Pour vermiculite into each burner pan to the point where

each pan is completely full. Level the vermiculite from right

to left to ensure an even flame pattern. See Figure 6.

J. For Propane Gas Installation

(for all units).

Fire Risk

Explosion Risk

Personal Injury Risk
An explosion could occur if a connection is

made directly to an unregulated propane

(LP) tank.

WARNING

• Lightly place dime size pieces of rock wool evenly on top

of the vermiculite to achieve a glowing ember effect. See

Figure 7.

Note: Be sure to not cover the pilot assembly (located on

the right side of the burner pan, installed in the vertical

position) with vermiculite.

Note: For best results, do not pack down the rock wool.

The placement of rock wool can have an effect on flame

pattern and may need to be adjusted to achieve a desired

appearance.

Fire Risk

Explosion Risk

Personal Injury Risk
Pour vermiculite into each burner pan (LP) to

the point where each pan is completely full.

Failure to do so may cause the lighting to be

delayed and this can be dangerous..

WARNING

Note: The state of Massachusetts requires that the

chimney flue damper, when used with gas logs, be welded

open or completely removed. In the Commonwealth of

Massachusetts this appliance must be installed by a

licensed plumber or gasfitter.