PERFORMANCE DATA NO. 06A020
ISSUED: 10/10/2006
ITEM: HOSHIZAKI MODULAR CRESCENT CUBER
MODEL: KM-650MWH
70/21
680
308
675
306
626
284
80/27
676
307
668
303
595
270
90/32
675
306
662
300
598
271
lbs./day kg./day
100/38
651
295
647
294
540
245
70/21
80/27
90/32
watts
100/38
70/21
662
2.51
729
2.76
1173
4.44
80/27
713
2.70
817
3.09
1457
5.52
90/32
729
2.76
890
3.37
1457
5.52
gal./day m
3
/day
100/38
980
3.71
1023
3.87
1977
7.49
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
231
16.2
231
16.2
238
16.7
80/27
231
16.2
231
16.2
242
17.0
90/32
231
16.2
231
16.2
240
16.9
PSIG kg/cm
2
G
100/38
235
16.5
233
16.4
249
17.5
70/21
50
3.5
51
3.6
53
3.7
80/27
51
3.6
54
3.8
54
3.8
90/32
51
3.6
56
3.9
56
4.0
PSIG kg/cm
2
G
100/38
51
3.6
56
3.9
57
4.0
TOTAL HEAT OF REJECTION FROM COMPRESSOR
1,400 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
WATER FLOW FOR CONDENSER
77 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
PRESSURE DROP OF COOLING WATER LINE
less than 10 PSIG
Note: Pressure data is recorded at 5 minutes into freezing cycle.
The data not in
bold
should be used for reference only.
2.1
TOTAL HEAT OF REJECTION FROM CONDENSER
10,000 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
SUCTION PRESSURE
HARVEST CYCLE TIME
HEAD PRESSURE
3.7
3.1
4.1
2.5
31
28
29
31
1036
1044
1055
1060
30
32
33
35
1028
1029
1040
1050
1051
1020
1027
1029
27
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC)
50/10
70/21
90/32
28
28
30
2.7
4.7
3.4
4.1
3.4
2.8
4.3
ENG.F-011.1.0205
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in
bold
should be used for reference only.
2. We reserve the right to make changes in specifications and design without prior
notice.
2. KM-650MWH (water-cooled)