e) Pump-Out Frequency Control (dip switch 5 & 6)

The pump motor drains the water tank at the frequency set by the pump-out frequency
control.
The pump-out frequency control is factory-adjusted to drain the water tank every 10
cycles, and no adjustment is required. However, where water quality is bad and the
icemaker needs a pump drain more often, the pump-out frequency can be adjusted as
shown in the table below.

Dip Switch Setting

Frequency

No. 5

No. 6

OFF

OFF

every cycle

ON

OFF

every 2 cycles

OFF

ON

every 5 cycles

ON

ON

every 10 cycles

f) Freeze Timer (dip switch 9 & 10)

CAUTION

Adjust to proper specification, or the unit may not operate correctly.

The freeze timer setting determines the maximum allowed freeze time to prevent
possible freeze-up issues. Upon termination of freeze timer, machine initiates the harvest
cycle. After 2 consecutive timer terminations, machine will shut down, possibly indicating
a problem.
The freeze timer is factory adjusted and no adjustment is required.

Dip Switch Setting

Time

(minutes)

No. 9

No. 10

OFF

OFF

60

OFF

ON

50

ON

OFF

70

ON

ON

60

g) Bin Control

CAUTION

When the ambient temperature is below 45°F (7°C), the bin control thermostat
operates to stop the icemaker even if the ice storage bin is empty. When the
thermostat is set in the prohibited range, the icemaker operates continuously
even if the ice storage bin is filled with ice. Setting in the prohibited range might
cause severe damage to the icemaker resulting in failure.

No adjustment is required under normal use, as the bin control is factory-adjusted. Adjust
it, if necessary, so that the icemaker stops automatically within 10 seconds after ice
contacts the bin control thermostat bulb.