beautypg.com

C. performance data, Km-650mah (air-cooled) – Hoshizaki MODULAR CRESCENT CUBER KM-650MWH User Manual

Page 28

background image

28

C. Performance Data

1. KM-650MAH (air-cooled)

PERFORMANCE DATA NO. 06A019

ISSUED: 10/10/2006

ITEM: HOSHIZAKI MODULAR CRESCENT CUBER
MODEL: KM-650MAH

70/21

589

267

566

257

526

238

80/27

572

259

537

243

490

222

90/32

566

257

512

232

467

212

lbs./day kg./day

100/38

555

252

501

227

426

193

70/21
80/27
90/32

watts

100/38

70/21

257

0.97

214

0.81

190

0.72

80/27

224

0.85

156

0.59

153

0.58

90/32

214

0.81

108

0.41

95

0.36

gal./day m

3

/day

100/38

163

0.62

105

0.40

84

0.32

70/21

80/27
90/32

min.

100/38

70/21
80/27

90/32

min.

100/38

70/21

225

15.8

246

17.3

270

19.0

80/27

241

17.0

275

19.3

295

20.7

90/32

246

17.3

298

21.0

320

22.5

PSIG kg/cm

2

G

100/38

249

17.5

303

21.3

341

24.0

70/21

53

3.7

55

3.9

58

4.1

80/27

54

3.8

57

4.0

61

4.3

90/32

55

3.9

59

4.2

63

4.4

PSIG kg/cm

2

G

100/38

56

3.9

60

4.2

67

4.7

Note: Pressure data is recorded at 5 minutes into freezing cycle.
The data not in

bold

should be used for reference only.

2.0

TOTAL HEAT OF REJECTION FROM CONDENSER

10,600 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

SUCTION PRESSURE

HARVEST CYCLE TIME

HEAD PRESSURE

3.6
3.0

3.9

2.1

38

32
33

37

1170
1209
1261
1280

35

38
40
43

1138

1141
1195
1240
1245

1100
1131
1141

30

APPROXIMATE ICE

PRODUCTION PER 24 HR.

APPROXIMATE ELECTRIC

CONSUMPTION

APPROXIMATE WATER

CONSUMPTION PER 24 HR.

FREEZING CYCLE TIME

WATER TEMP. (ºF/ºC)

AMBIENT TEMP.

(ºF/ºC)

50/10

70/21

90/32

31

32

35

2.2

4.6

3.1

3.9
3.0

2.2

4.1

ENG.F-011.1.0205

Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in

bold

should be used for reference only.

2. We reserve the right to make changes in specifications and design without prior

notice.

This manual is related to the following products: