SPECIFICATIONS
DIMENSIONS - MINI-COMPACT “MC” SERIES
INSTALLATION
LOCATION
For the most effective operation, install the booster
heater as close as possible to the commercial
dishwasher. The location must have a solid
foundation along with being clean and dry. Adequate
front clearance is required to allow for accessibility
to the control compartment. Location must have
adequate clearance to allow for inspection, testing
or replacement of pressure/temperature relief valve.
WARNING
To avoid any injury or damage do not install the
unit in an area where flammable liquids or
combustible vapors are present.
WARNING
To avoid personal injury and to assure safe
operation install the booster heater as close as
possible to the commercial dishwasher. Employ
recirculation if distance between booster and
commercial dishwasher exceeds National
Sanitation Foundation (NSF) specifications of
five (5) linear feet (1524 mm).
WARNING
To avoid personal injury or damage to
equipment, the booster heater must be installed
by qualified, trained installers. Installation must
conform to all local electrical and plumbing
codes. Check with your local plumbing and
electrical inspectors for proper procedures and
codes.
CAUTION
Unit is not weatherproof. For safe and proper
operation the unit must be located indoors
where the ambient air temperature is constant
and is a minimum of 70°F (21°C).