Technical data – haier MAGNUM 232738 User Manual
Page 28
Technical Data
28
309477F
Technical Data
dx Roller/Spray System
XR9 Sprayer
Working pressure range
0 - 207 bar, 21 MPa (0 - 3,000 psi)
0 - 207 bar, 21 MPa (0 - 3,000 psi)
Electric motor
3.5 AMP (open frame, universal)
4.5 AMP (permanent magnet DC)
Operating horsepower
3/8
7/8
Maximum delivery (with tip)
0.91 lpm (0.24 gpm)
1.44 lpm (0.38 gpm)
Paint hose
7.6 m (25 ft) x 1/4 in.
15.2 m (50 ft) x 1/4 in.
Maximum tip hole size
0.38 mm (0.015 in.)
0.48 mm (0.019 in.)
Weight, sprayer only
6 kg (13 lb)
Weight, sprayer, hose & gun
7.8 kg (17 lb)
Dimensions:
Length
41 cm (16 in.)
49.5 cm (19.5 in.)
Width
46 cm (18 in.)
48.3 cm (19 in.)
Height
53 cm (21 in.)
101.6 cm (40 in.)*
*Height with folded handle is 66 cm (26 in.)
Power cord
3 wire, 1.0 mm
2
x 2.0 m (78 in.)
3 wire, 1.0 mm
2
x2.0 m (78 in.)
Fluid inlet fitting
Fluid outlet fitting
1/4 npsm external thread
1/4 npsm external thread
Inlet screen on suction tube
450 micron (35 mesh)
450 micron (35 mesh)
Wetted parts, pump & hose
stainless steel, brass, ultra-high
molecular weight polyethylene
(UHMWPE), carbide, nylon,
aluminum, PVC, polypropylene,
fluroelastomer
stainless steel, brass, leather,
ultra-high molecular weight
polyethylene (UHMWPE), carbide,
nylon, aluminum, PVC,
polypropylene, fluroelastomer
Wetted parts, gun
aluminum, brass, carbide, nylon,
plated steel, stainless steel,
UHMWPE, zinc
aluminum, brass, carbide, nylon,
plated steel, stainless steel,
UHMWPE, zinc
Generator requirement
1500 Watt minimum
1500 Watt minimum
Electrical power requirement
220-240 V AC, 50/60 Hz, 1 phase,
10 A
220-240 V AC, 50/60 Hz, 1 phase,
10 A
Storage temperature range *
❖
-35° to 71°C (-30° to 160°F)
-35° to 71°C (-30° to 160°F)
Operating temperature range
✔
4° to 46°C (40° to 115°F)
4° to 46°C (40° to 115°F)
*
When pump is stored with non-freezing fluid. Pump damage will occur if water or latex paint freezes in pump.
❖ Damage to plastic parts may result if impact occurs in low temperature conditions.
✔ Changes in paint viscosity at very low or very high temperatures can affect sprayer performance.