haier MAGNUM 232738 User Manual
Page 12
Advanced Troubleshooting
12
309477F
Basic electrical problems
Motor overheated
Allow motor to cool for 30 minutes. Retry.
Electrical outlet is damaged
Reset building circuit breaker or replace building
fuse. Try another outlet.
Check electric supply with volt meter. Meter must
read 200-260V AC. If voltage is too high, do not
plug sprayer in until outlet is corrected.
Control board leads are
improperly fastened or
improperly mated
Replace any loose terminals. Make sure all leads
and harnesses are firmly connected.
Check pressure control harness connection on
front side of drive housing.
Clean control board terminals. Securely reconnect
leads.
Motor brushes are worn.
Check length of BOTH brushes (brushes do not
wear evenly on both sides of the motor). Brush
length must be 6.4mm (0.25 in). If brushes are
worn replace motor using Motor Kit, page 18.
Motor armature commutator
damaged
Check for burn spots, gouges and extreme
roughness. Have motor shop resurface
commutator if possible, or replace motor using
Motor Kit, page 18.
Motor armature shorting
Check for shorts using armature tester (growler)
or perform spin test, Motor Diagnostic, page 19.
If shorts are evident, replace motor using Motor
Kit, page 18.
Control board damaged.
CAUTION: Do not perform
control board diagnostics until
you have determined the
armature is good. A bad
armature can burn out a good
control board.
See Control Board Diagnostics, page 19.
Replace control board if damaged using Control
Board Kit, page 18.
Sprayer Wiring Problems
NOTE: Remove enclosure
mounting screws and pull
enclosure away from drive
housing. Take care not to pull
on leads from electrical cord
and power switch.
Sprayer electrical cord
damaged
1. Unplug sprayer electrical cord.
2. Disconnect black electrical cord wire at
power switch
3. Unplug in-line connection white cord wire.
4. Plug in electrical cord
5. Test voltage between black and white
wires. Meter must read 200-260 V AC.
6. Replace electrical cord if no voltage.
Sprayer power switch damaged
1. Unplug sprayer electrical cord.
2. Disconnect black control board wire at
power switch.
3. Unplug in-line connection white cord wire.
4. Plug in electrical cord.
5. Turn power switch ON.
6. Test voltage between open terminal of
power switch and white electrical cord wire.
Meter must read 200-260 V AC.
7. Replace power switch if no voltage.
Specific Problem
Cause
Solution