beautypg.com

Image menu – Hitachi CP-D10 User Manual

Page 29

background image

29

IMAGE menu

IMAGE menu

From the IMAGE menu, items shown in the table
below can be performed.
Select an item using the ▲/▼ cursor buttons, and
press the ► cursor (or the ENTER) button to execute
the item. Then perform it according to the following
table.

Item

Description

ASPECT

Using the ▲/▼ cursor buttons switches the mode for aspect ratio.
For a computer signal

NORMAL

4:3

16:9

16:10

NATIVE


For a video signal, s-video signal or component video signal

4:3

16:9

16:10

14:9

NATIVE


For no signal

4:3 (fixed)

• The NORMAL mode keeps the original aspect ratio of the signal.
• The on-screen menu might be displayed outside of the image display
area depending on the adjustment value of the ASPECT, D-ZOOM
and KEYSTONE. Changing the values of ASPECT, D-ZOOM and
KEYSTONE may fix the symptom.

OVER SCAN

Using the ◄/► cursor buttons adjusts the over-scan ratio.

Small (It magnifies picture)

Large (It reduces picture)

• This item can be selected only for a video, s-video and component
video signal.
• When this adjustment is too large, certain degradation may appear at
the frame area of the picture. In such a case, please adjust small.

V POSITION

Using the ◄/► cursor buttons adjusts the vertical position.

Down

Up

• Over-adjusting the vertical position may cause noise to appear on the
screen. If this occurs, please reset the vertical position to the default
setting. Pressing the RESET button on the remote control when the V
POSITION is selected will reset the V POSITION to the default setting.
• When this function is performed on a video signal or s-video signal,
the range of this adjustment depends on the OVER SCAN (

above)

setting. It is not possible to adjust when the OVER SCAN is set to 10.

H POSITION

Using the ◄/► cursor buttons adjusts the horizontal position.

Right

Left

• Over-adjusting the horizontal position may cause noise to appear on
the screen. If this occurs, please reset the horizontal position to the
default setting. Pressing the RESET button on the remote control when
the H POSITION is selected will reset the H POSITION to the default
setting.
• When this function is performed on a video signal or s-video signal,
the range of this adjustment depends on the OVER SCAN (

above)

setting. It is not possible to adjust when the OVER SCAN is set to 10.