beautypg.com

5. selecting a location, 6. connecting gas/air supply, 7. connecting work clamp – Hobart Welding Products AIRFORCE 700I User Manual

Page 17

background image

.

A complete Parts List is available at www.MillerWelds.com

OM-244 013 Page 13

4-5. Selecting A Location

loc_2 3/96 - Ref. 244 405-A

!

Do not move or operate unit

where it could tip.

18 in.

(460 mm)

18 in.

(460 mm)

!

Special installation may be

required where gasoline or

volatile liquids are present ï

see NEC Article 511 or CEC

Section 20.

4-6. Connecting Gas/Air Supply

Ref. 244 423-A

.

Use only clean, dry air with 90
to 120 psi (621 to 827 kPa)
pressure.

1

Gas/Air Inlet Opening

2

Hose

3

Teflon Tape

Obtain hose with 1/4 NPT right-
hand thread fitting. Wrap threads
with teflon tape (optional) or apply
pipe sealant, and install fitting in
opening. Route hose to gas/air
supply.

Tools Needed:

3

From Gas/Air

Supply

1

2

9/16 in.

4-7. Connecting Work Clamp

.

Do not connect work clamp to
the portion of the workpiece
that will fall when cut.

1

Work Clamp

2

Workpiece

Connect work clamp to a clean,
paint-free location on workpiece, as
close to cutting area as possible.

1

2

Ref 803 915-A