1. specifications – Hobart Welding Products AIRFORCE 700I User Manual
Page 15
.
A complete Parts List is available at www.MillerWelds.com
OM-244 013 Page 11
SECTION 4 ï INSTALLATION
4-1. Specifications
Power Supply
Input
Rated AC phase (PH) and line frequency (Hz)
1 PH
60 Hz
— —
Rated Input Voltage (U
1
) and rated Input
Current (I
1
) and I
1
eff at rated output. I
1
eff used
to determine power cord rating
Volts AC RMS ï (U
1
)
Amps RMS ï (I
1
)
I
1
eff
208 Volts
33
23.3
230 Volts
30
21.2
Power Factor/KVA/KW at Rated Output
Volts AC RMS ï (U
1
)
Power Factor
KVA/KW
208 Volts
0.98
6.8/6.6
230 Volts
0.98
6.8/6.6
Peak KW at Arc Stretch
10.1 KW
— —
— —
Output
Rated Open Circuit Voltage (U0) Type
400 Volts DC/Electrode Negative
— —
— —
Output Characteristic
Constant Current
— —
— —
Output Current Range
20-40 A
— —
— —
Output Current and Voltage Rating at Rated
Input Voltage (I
2
and U
2
at U
1
)
Amps DC ï (I
2
)
Volts DC ï (U
2
)
Volts AC
RMS ï (U
1
)
40 A
140 Volts DC
208 Volts
40 A
140 Volts DC
230 Volts
Duty Cycle at 1045 F (405 C) at rated conditions
(U
1
, I
1
, U
2
, I
2
) based on a 10 minute period
Duty Cycle %
Amps DC ï (I
2
)
Volts AC
RMS ï (U
1
)
50
40 A
208 Volts
50
40 A
230 Volts
General
Operating Temperature
5° to 104° F (ï15° to 40° C)
— —
— —
IP Code ï Degree of protection provided by
enclosure
IP23CS
— —
— —
IP ï International Protection
— —
— —
2 ï No ingress of foreign objects 12.5 mm
(0.5 in.)
— —
— —
3 ï No harmful ingress spraying water
— —
— —
C ï AC line circuits protected against ingress of
tool ≥ 2.5 mm dia x 100 mm long (0.1 in. x 4 in.)
— —
— —
S ï Fan stationary during water test
— —
— —
Toppling or tilting
Up to 15° incline
— —
— —
Gas Type
Air or Nitrogen
— —
— —
Gas Quality
Clean, moisture-free, oil-free
— —
— —
Gas Inlet Flow and Pressure
4.8 SCFM (85 L/min)
90 PSI (621 kPa)
Min
120 PSI (827
kPa) Max
Gas Filtering
Particulates to 5 microns
— —
— —
Torch
Mild Steel capacities (see Section 5-2 for
cutting speeds vs material type and thickness)
— —
— —
— —
Rated Capacity (edge start)
5/8 in. at 9 ipm (229 mm/min)*
— —
— —
Sever Cut Capacity (edge start)
7/8 in. (22 mm)
— —
— —
Pierce Capacity
5/16 in. (8 mm)
— —
— —