beautypg.com

Warning, Caution, D. maintenance task list – Heat & Glo Fireplace EXCLAIM-36T-C User Manual

Page 36: E. chimney fire

background image

Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06

36

Fire Risk

• Do not use chimney cleaners or

À ame

colorants in your

¿ replace.

Will corrode chimney.

WARNING

D. Maintenance Task List

Asphyxiation Risk
Fire Risk

Annual inspection by qualified technician

recommended.

Check:

Condition of doors, surrounds and fronts

• Condition of glass and glass assembly
• Obstructions of combustion and ventilation

air

• Gas

connections

and

¿ ttings (if present)

• Obstructions of termination cap
• Refractory

panels

Clean:
• Glass
• Air passageways, grilles

WARNING

Handle glass assembly with care.
When cleaning glass door:
• Avoid striking, scratching or slamming

glass.

• Do NOT use abrasive cleaners.

Use a hard water deposit glass cleaner on
white

¿ lm.

• Do NOT clean glass when it is hot.

CAUTION

E. Chimney Fire

In the event of a chimney

¿ re:

• Have the chimney and adjacent structure inspected by

quali

¿ ed professionals. Hearth & Home Technologies

recommends that NFI or CSIA certi

¿ ed professionals, or

technicians under the direction of certi

¿ ed professionals,

conduct a minimum of an NFPA 211 Level 2 inspection of
the chimney.

• Replace components of the chimney and

¿ replace as

speci

¿ ed by the professionals.

• Ensure all joints are properly engaged and the chimney

is properly secured.

A chimney

¿ re can permanently damage your chimney sys-

tem. Failure to replace damaged components and make
proper repairs creates risk of

¿ re.

Inspect

Maintenance Tasks

Screens

1. Assess condition of screen and replace as necessary. Screens are required.

2. Verify maintenance of proper clearance to combustible household objects.

Glass Doors

1. Inspect glass panels for cracks. Replace if this condition is present.

2. Con

¿ rm there is no damage to glass or glass frame. Replace as necessary.

3. Clean glass using a non-abrasive cleaner such as Brasso©.

Circulation Compartment

1. Remove any foreign objects.

2. Verify unobstructed air circulation.

Firebox

1. Inspect condition of refractory. Replace if crumbly, deteriorated, or if cracks exceed 1/4 in. (6 mm).

Chimney

1. Inspect for blockage or obstruction such as bird nests, leaves, etc.

2. Con

¿ rm that termination cap remains clear and unobstructed by plants, etc.

3. Verify that termination cap clearance to subsequent construction (building additions) has been maintained.

4. Inspect for corrosion or separation.

5. Verify weather stripping, sealing and

À ashing remain intact.

6. Inspect for creosote and remove as needed. (See Sections 10 and 11)

Grate

1. If grate burns out, it should be replaced only with the grate speci

¿ ed on the rating plate and in the replacement

parts list for this

¿ replace.