beautypg.com

Electrical service guide for 230 vac model, Installing wire spool and adjusting hub tension, 8. electrical service guide for 230 vac model – Hobart Welding Products HANDLER OM-925 217 694A User Manual

Page 21: 9. installing wire spool and adjusting hub tension

background image

OM-925 Page 17

Return To Table Of Contents

4-8.

Electrical Service Guide For 230 VAC Model

Input Voltage

230

Input Amperes At Rated Output

20

Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes

Circuit Breaker

1

, Time-Delay

2

25

Normal Operating

3

30

Min Input Conductor Size In AWG

14

Max Recommended Input Conductor Length In Feet (Meters)

67

(20)

Min Grounding Conductor Size In AWG

14

Reference: 1999 National Electrical Code (NEC)

1 Choose a circuit breaker with time-current curves comparable to a Time Delay Fuse.

2 “Time-Delay” fuses are UL class “RK5” .
3 “Normal Operating” (general purpose − no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and

above).

4-9.

Installing Wire Spool And Adjusting Hub Tension

When a slight force is needed
to turn spool, tension is set.

1/2 in

Tools Needed:

803 012 / 803 013 -B / Ref. 802 971-C

Installing 8 in (203 mm) Wire Spool

Installing 4 in (102 mm) Wire Spool

When a slight force is needed
to turn spool, tension is set.

Retaining ring used

with 8 in (203 mm)

spool only.

Adapter used with

8 in (203 mm)

spool only.