Electrical service guide for 230 vac model, Installing wire spool and adjusting hub tension, 8. electrical service guide for 230 vac model – Hobart Welding Products HANDLER OM-925 217 694A User Manual
Page 21: 9. installing wire spool and adjusting hub tension
OM-925 Page 17
4-8.
Electrical Service Guide For 230 VAC Model
Input Voltage
230
Input Amperes At Rated Output
20
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
Circuit Breaker
1
, Time-Delay
2
25
Normal Operating
3
30
Min Input Conductor Size In AWG
14
Max Recommended Input Conductor Length In Feet (Meters)
67
(20)
Min Grounding Conductor Size In AWG
14
Reference: 1999 National Electrical Code (NEC)
1 Choose a circuit breaker with time-current curves comparable to a Time Delay Fuse.
2 “Time-Delay” fuses are UL class “RK5” .
3 “Normal Operating” (general purpose − no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and
above).
4-9.
Installing Wire Spool And Adjusting Hub Tension
When a slight force is needed
to turn spool, tension is set.
1/2 in
Tools Needed:
803 012 / 803 013 -B / Ref. 802 971-C
Installing 8 in (203 mm) Wire Spool
Installing 4 in (102 mm) Wire Spool
When a slight force is needed
to turn spool, tension is set.
Retaining ring used
with 8 in (203 mm)
spool only.
Adapter used with
8 in (203 mm)
spool only.