background image

CHAPTER 3 WIRING, CONNECTING

3

3.1 TERMINAL ASSIGNMENT OF DIGITAL INPUT OPTION BOARD

Figure 3-1a shows terminal assignment, Figure 3-1b shows terminal standard connection.

In case of sink type interface, power is supplied to input terminal (D0 to D15, STRB) by short circuit between

P24B terminal and PLCB terminal.

D5

D4

D3

D2

D1

D0 STRB

P24B

TM2

Terminal assignment

CM1 PLCB

SEQ CMB D15 D14 D13 D12 D11

TM1

Terminal assignment

D10

D9

D8

D7

D6

TM1

TM2

Figure 3-1a Terminal assignment

RY

SEQ

CMB

D15

D0

STRB

CM1

PLCB

P24B

D14

(Data input signal)

(Sequence error output terminal)

(Strobe)

(Common terminal)

(Common terminal)

(short circuit)

Inverter digital option printed board