CHAPTER 3 WIRING, CONNECTION

5

3.3 SPECIFICATION OF TERMINAL

Table 3-3 shows specification of terminal.

Table 3-3 Specification of terminal

Terminal

symbol

Terminal name

Specification

Electric characteristics

D15 to D0

(Hereinafter

called as

Dn)

Data input terminal

Input

STRB

Strobe terminal
(Data take in command
signal terminal)

Photo coupler input
(1a contact signal)
Sink source type

Input impedance : 4.7k Ù
Allowable

SEQ

Sequence error signal

(Data input error signal
output terminal)

Sink source type

Between SEQ and CMB

Voltage drop at on : less than 4V
Allowable max. voltage : DC27V
Allowable max. current : 50mA

Output

CMB

Common terminal for
sequence error signal
output

Common terminal for
sequence error signal output

Note)

P24B

Power source terminal
for interface

DC24V power source for
contact input signal
In case of selecting source
logic, contact input common.

Allowable max. current : 90mA

Power
source

CM1

Power source terminal
for interface Common
terminal

Common terminal for data
input terminal, power source
for interface and strobe
terminal

Note)

Note) Never connect to earth of ground.

3.4 APPLICABLE WIRING

Make sure to use applicable wiring as the following items.

wire that is shield

less than 0.5mm

2.

Connect the wire which peeling length of sheathed signal wire is 5 –

In case of connecting twist wire, make sure not to loose

Use signal wire which max, outside diameter is less than 2.0mm

2

SEQ

CMB

DC24V

SJ-DG

CMB

COM

DC24V

SJ-DG