beautypg.com

Chapter 4 setting – Hitachi SJ-DG User Manual

Page 13

background image

CHAPTER 4 SETTING

7

It is possible to select input mode by combination of dip switch and rotary switch on the option printed board.

Table 4-4 shows table of input mode.

(Viewpoint of table of input mode)

Example 1) In one time input mode, switch setting which sets setting frequency by 1Hz resolution and binary

input.

TYPE

CODE

1

2

BIN

PAC

2

Example 2) In two dividing input, switch setting which sets setting frequency with 0.1Hz resolution and BCD

input, and in case of setting acceleration and deceleration time by BCD input, 0.1sec.resolution.

TYPE

CODE

1

2

BCD

DIV

2

Table 4-4 Table of input mode

Dip switch

Rotary

switch

Setting frequency

Acceleration and

deceleration time setting

Torque

limit

setting

Position

setting

TYPE

CODE

Setting resolution

Switch No.

1

2

Setting

code

0.01Hz

0.1Hz

1Hz

Rate

0.01sec

0.1sec

1sec

1%

1pulse

0

O

1

O

2

O

3

O

4

O

5

PAC

(One

time

input

mode at

OFF)

6

O

0

O

1

O

2

O

O

3

O

4

O

5

O

O

6

O

7

O

8

O

O

9

O

A

O

BIN

(Binary

input at

OFF)

/

BCD

(BCD

input at

ON)

DIV

(Dividing

input

mode at

ON)

B

O

O

O

O

Precaution O shows input mode set by switch setting. Make sure not to set switch setting except O because they are for

adjustments of factory.