beautypg.com

1 function, Chapter 5 function, 1 one time binary input – Hitachi SJ-DG User Manual

Page 15: 2 one time bcd input

background image

CHAPTER 5 FUNCTION

9

Setting of dip switch TYPE

1

2

BIN

PAC

Setting of dip switch TYPE

1

2

BCD

PAC

5.1 FUNCTION

5.1.1 ONE TIME BINARY INPUT

It is possible to select frequency setting, torque limit setting or

position setting of one time data input by rotary switch CODE.

Figure 5.1.1shows data bit construction of one time binary input.

(Example of setting) In case of setting frequency to 60.0Hz by 0.1Hz

resolution

(Setting of rotary switch CODE --- 1).

(1) Input value which 60 multiplies 10 to D15 - D0 terminal by 16 bits binary value.

(1) 60 times10 = 600 ---- 0000001001011000 (Binary)
(2) When data input is definite, turn the strobe signal on.
(3) Turn the strobe signal off.

Precaution Refer to 5.3 ”DATA INPUT TIMING” for signal input timing.

5.1.2 ONE TIME BCD INPUT

It is possible to select frequency setting, torque limit setting or position

setting of one time data input by rotary switch CODE.
Figure 5.1.2 shows data bit construction of one time BCD input.
(Example of setting) In case of setting frequency to 30.0Hz resolution by

0.01Hz

(Setting of rotary switch CODE ---- 1)

(1) Input value which 30 multiplies 100 to D15 to D0 terminal by BCD value.

30 times100 = 3000 ---- 0011000000000000 (binary)

(2) When data input is definite, turn the strobe signal on.
(3) Turn the strobe signal off.

D11

D10

D 9

D 8

D 7

D 6

D 5

D 4

D 3

D 2

D 1

D 0

(Higher)

(Lower)

Setting

D15

D14

D13

D12

Figure 5.1.1 Data bit construction of one time binary input

D11

D10

D 9

D 8

D 7

D 6

D 5

D 4

D 3

D 2

D 1

D 0

(Higher)

(Lower)

Setting data 4

D15

D14

D13

D12

Setting data 3

Setting data 2

Setting data 1

Figure 5.1.2 Data bit construction of one time BCD input

D11

D10

D 9

D 8

D 7

D 6

D 5

D 4

D 3

D 2

D 1

D 0

16 bits data

0

0

0

0

0

0

0

0

1

1

1

1

0

0

0

0

D12

D13

D14

D15