beautypg.com

Heath Zenith Motion Sensing Security Light UT-9250-BZ User Manual

Page 8

background image

-8-

598-1290-02

Finish Mounting

Align the cover plate, gasket, and the mounting

bracket hole. Secure with M5 x 0.8 x 40 mm
mounting screw supplied.

Push the rubber plug firmly into place.

If not installed on a weatherproof box, caulk

between the cover plate and mounting sur-

face with silicone weather sealant.

Adjust the lamp holders by loosening the

thumb screws but do not rotate the lamp hold-
ers more than 180° from the factory setting.
When screwing in the floodlamps, do not
overtighten.

To avoid water damage and
electrical shock, keep lamp
holders aimed below horizontal.

Specifications

Range . . . . . . . . . . . . . . . 70 feet (21.0 m); 100 feet

(30.5 m) with Range Boost.
Varies with surrounding
temperature.

Sensing Angle . . . . . . . . . Up to 270° (Adjustable)

Fixture Load . . . . . . . . . . Up to 300 Watts Maximum

Tungsten Incandescent [Up
to 150 Watts maximum each
lamp holder.]

Sensor Load Capacity . . . Up to 1000 Watts (8.3 amps)

Maximum Tungsten Incan-
descent

Power Requirements . . . . 120 VAC, 60 Hz

Operating Modes . . . . . . . TEST, AUTO, and MANUAL

OVERRIDE

Time Delay . . . . . . . . . . . 1, 5, 20 minutes

HeathCo LLC reserves the right to discontinue
products and to change specifications at any time
without incurring any obligation to incorporate new
features in products previously sold.

Rubber Plug

This manual is related to the following products: