NOTICE

Clean the Spray Gun IMMEDIATELY after use.

Delayed or inadequate cleaning will permanently clog the Spray Gun.

Page 15

For technical questions, please call 1-800-444-3353.

Item 92841

SAFETY

Op

ERA

TION

M

AINTENANCE

SETU

p

Cleaning

Solvent Selection
Follow the paint manufacturer’s recommendations for cleaning,

solvent type, and disposing of used solvent.
IMpORTANT: Do not use mineral spirits on latex paints or the

mixture will congeal, making it very difficult to remove.

WARNING! TO pREVENT FIRE,

IF A FLAMMABLE SOLVENT NEEDS TO BE USED,

ADHERE TO THE FOLLOWING:
a.

Follow solvent manufacturer’s clean up instructions and safety precautions.

b.

Flush Spray Gun a full hose length from air compressor.

c.

If collecting flushed solvents in metal container, transfer to

nonmetal container, and flush metal container.

d.

Work far away from any ignition sources in a vapor free area.

e.

Keep class ABC fire extinguisher nearby.

After each use:
1. Empty the Paint Cup and clean

it with the solvent.

2. Fill the Paint Cup with solvent and spray

it through the Spray Gun into a container,

while shaking the Spray Gun. Once the

Paint Cup is empty, repeat the process

until the solvent comes out clean.

3. Disconnect from the air source.
4. After disconnecting, point the Spray Gun into

the spent solvent container and squeeze the

Trigger again to make sure no air remains.

5. Remove Nozzle and soak it in solvent

until it is clean. Use old toothbrush

and toothpicks to remove any paint.

CAUTION: Do not immerse Spray Gun.
Note: Do not use metal objects to clean the

Nozzle to prevent damage to the passages.
6. Inspect fluid needle and make sure

it is not bent. If it is bent, have it

replaced by a qualified technician.

7. Use appropriate solvent

(see

Solvent Selection, left)

to wipe down Spray Gun body.

8. Lubricate Spray Gun after cleaning.

A non-silicon oil or a light lubricant may be

used on threaded connections before storing.

Solution Disposal
After cleaning, dispose of cleaning solution according to the solution