beautypg.com

Connecting work clamp and gas/air supply, 6. connecting work clamp and gas/air supply – Hobart Welding Products 625 User Manual

Page 16

background image

.

A complete Parts List is available at www.HobartWelders.com

OM-926 Page 12

4-6.

Connecting Work Clamp and Gas/Air Supply

1

Work Clamp

2

Workpiece

Connect work clamp to a clean,
paint-free location on workpiece, as
close to cutting area as possible.

.

Use only clean, dry air with 90
to 120 psi (621 to 827 kPa)
pressure. Prevent moisture
from entering air supply at
extreme cold temperatures.

3

Gas/Air Inlet Opening

4

Hose

.

Hose must have a minimum
inside diameter of 3/8 in
(9.5 mm).

5

Teflon Tape

Obtain hose with 1/4 NPT right-
hand thread fitting. Wrap threads
with teflon tape (optional) or apply
pipe sealant, and install fitting in
opening. Route hose to gas/air
supply.

Or

Install supplied quick connect male
1/4 in NPT pipe fitting.

Connect female quick connect
fitting to pipe fitting.

Route hose to gas/air supply.

Y

Incorrect plasma gas can
cause torch and power
source damage. Use only air
or nitrogen for the plasma
gas.

Tools Needed:

5/8, 1-1/8 in

From Gas/Air Supply

Ref. 801 319-C / Ref. 803 221

Rear of Unit

1

2

5

3

4

AIR/N

2

90-120 psi