LP Conversion Instructions

With the installation of this conversion kit,

the cooktop should operate on LP gas at 10

of water column pressure.

The pressure regulator must be connected in series

with the manifold of the cooktop and must remain
in series with the supply line. For proper operation,
the maximum inlet pressure to the regulator must
be no more than 14

water column pressure for

LP gas.

When checking the regulator, the inlet pressure

must be at least 1

greater than the regulator output

setting. If the regulator is set for 10

of water column

pressure, the inlet pressure must be at least 11.

IMPORTANT –

Disconnect the cooktop and

the individual shut-off valve from the gas supply piping
system during any pressure testing of that system at test
pressures greater than 1/2 psig. Isolate the cooktop from
the gas supply piping system by closing the individual
manual shut-off valve to the cooktop during any pressure
testing of the gas supply piping system at test pressures
equal to or greater than 1/2 psig.

GAS SUPPLY

BEFORE YOU BEGIN, TURN OFF THE GAS SUPPLY AT
THE SHUT-OFF VALVE. DISCONNECT THE ELECTRICAL
SUPPLY FROM THE COOKTOP.

TURN OFF GAS AND
ELECTRIC SUPPLY

CONVERT THE PRESSURE REGULATOR

Locate the pressure regulator under the front
of the cooktop.

A

1

Remove the nut from the pressure regulator with
an adjustable wrench.

B

Twist and remove the conversion plug from the inside
of the nut. Flip the conversion plug over; then insert,
twist and lock it back into place in the nut.

C

Reinstall the nut onto the regulator.
Apply the LP Conversion label next to the Rating Plate.

E

D

Shut-off valve

Electrical supply

Nut

Natural gas

LP gas

Nut

Natural gas

LP gas