H. startup caution, Fig. 6 – Hoshizaki SELF-CONTAINED CRESCENT CUBER L1F015102 User Manual
Page 16

13
H. Startup
CAUTION
1. All parts are factory-adjusted. Improper adjustments may result in failure.
2. If the unit is turned off, wait for at least 3 minutes before restarting the
icemaker to prevent damage to the Compressor.
3. To prevent damage to the Water Pump, do not leave the Control Switch in
the “SERVICE” position for extended periods of time when the Water Tank
is empty.
1) Open the Water Supply Line Shut-off Valve.
2) Remove the Louver.
3) Move the Control Switch on the Control Box to
the “ICE” position.
4) Turn on the power supply and allow the
icemaker to operate for 5 minutes to fill up the
Water Tank.
5) Move the Control Switch to the “SERVICE”
position. Move the Service Switch to the
“WASH” position.
6) Allow the icemaker to run for 5 minutes.
7) Move the Service Switch to the “DRAIN”
position.
8) Allow the icemaker to drain for 2 minutes.
9) Turn off the power supply.
10) Move the Control Switch to the “ICE” position.
11) Replace the Louver in its correct position.
12) Clean the Storage Bin using a neutral cleaner.
Rinse thoroughly after cleaning.
13) Turn on the power supply to start the automatic
icemaking process.
Fig. 6
Control Box
Control Switch
Service Switch
SER
VICE
OFF
CIRCULA
TE
ICE
DRAIN
WASH