12
C. Check Firebox Refractory
Frequency: After each ash removal
By: Homeowner
D. Inspect Grate
Frequency: After each ash removal
By: Homeowner
Inspect grate for:
• Warping or sagging 1-1/2 in. (38 mm) or more
• Broken
welds
• Burn-through of grate bars
For safe operation, replace only with an approved grate
from Hearth & Homes Technologies Inc.
WARNING! Risk of Fire! Inspect fi replace refractory.
Crumbling, deteriorated refractory can allow overheating
of surrounding materials.
Expansion and contraction will cause minor cracking of
the refractory. This is normal. The refractory will require
periodic replacement depending on use.
The panels should be replaced if
• Cracks exceed ¼ inch (6 mm) in width,
• Metal is exposed behind the refractory,
• Large pieces of refractory fall out.
E. Glass Cleaning
Frequency: As desired
By: Homeowner
Clean glass with a non-abrasive commercially available
cleaner or ashes:
• Light
deposits
- Use household glass cleaner
• Heavy
deposits
- Use wood ash on damp cloth or,
- Use
commercial
fi replace glass cleaner (consult with
your dealer)
CAUTION! Handle glass assembly with care. Glass is
breakable.
• Avoid striking, scratching or slamming glass
• Avoid abrasive cleaners
• DO NOT clean glass while it is hot
Heat & Glo • HST-48D US-CAN • 4012-040 • Rev F • 11/08