beautypg.com

Hearth and Home Technologies HST-48D User Manual

Page 12

background image

12

C. Check Firebox Refractory

Frequency: After each ash removal
By: Homeowner

D. Inspect Grate

Frequency: After each ash removal
By: Homeowner

Inspect grate for:

• Warping or sagging 1-1/2 in. (38 mm) or more
• Broken

welds

• Burn-through of grate bars
For safe operation, replace only with an approved grate
from Hearth & Homes Technologies Inc.

WARNING! Risk of Fire! Inspect fi replace refractory.
Crumbling, deteriorated refractory can allow overheating
of surrounding materials.

Expansion and contraction will cause minor cracking of
the refractory. This is normal. The refractory will require
periodic replacement depending on use.

The panels should be replaced if

• Cracks exceed ¼ inch (6 mm) in width,
• Metal is exposed behind the refractory,
• Large pieces of refractory fall out.

E. Glass Cleaning

Frequency: As desired
By: Homeowner

Clean glass with a non-abrasive commercially available
cleaner or ashes:

• Light

deposits

- Use household glass cleaner

• Heavy

deposits

- Use wood ash on damp cloth or,
- Use

commercial

fi replace glass cleaner (consult with

your dealer)

CAUTION! Handle glass assembly with care. Glass is
breakable.
• Avoid striking, scratching or slamming glass
• Avoid abrasive cleaners
DO NOT clean glass while it is hot

Heat & Glo • HST-48D US-CAN • 4012-040 • Rev F • 11/08