Verifone® ruby terminal default settings, Gilbarco® terminal default settings, Verifone – Honeywell VOYAGER 1250G User Manual
Page 33: Gilbarco, Ruby terminal default settings, Terminal default settings

2 - 9
Verifone
®
Ruby Terminal Default Settings
Scan the following Plug and Play code to program the scanner for a Verifone
Ruby terminal. This bar code sets the baud rate to 1200 bps and the data for-
mat to 8 data bits, Mark parity, 1 stop bit and RTS/CTS no timeout. It also adds
a line feed (LF) suffix and programs the following prefixes for each symbology:
Gilbarco
®
Terminal Default Settings
Scan the following Plug and Play code to program the scanner for a Gilbarco
terminal. This bar code sets the baud rate to 2400 bps and the data format to 7
data bits, even parity, 2 stop bits. It also adds a carriage return (CR) suffix and
programs the following prefixes for each symbology:
Symbology
Prefix
UPC-A
A
UPC-E
A
EAN-8
FF
EAN-13
F
Symbology
Prefix
UPC-A
A
UPC-E
E0
EAN-8
FF
EAN-13
F
Verifone Ruby Settings
Gilbarco Settings