beautypg.com

Menu functions – Husqvarna 230 ACX User Manual

Page 54

background image

English - 55

6. MENU FUNCTIONS

Test IN (3-2-4)

The Test IN (3-2-4) function is used to test how
Automower™ finds its way into the charging
station.

When the function is selected the mower will
immediately follow the boundary wire, guide 1 or
guide 2, depending on which one it finds first, in
to the charging station. If there is a passage and
the mower can not run through it, the Corridor
width
value is set too high. When Test IN is
activated, the mower runs at the greatest
distance from the wire that the selected corridor
width permits.

The adjacent picture shows how Automower™
negotiates a passage when a value of 8 is set for
the Corridor width, but not when a value of 10 is
set.

Test OUT (3-2-5)

The Test OUT (3-2-5) function is used to try
different charge exit settings and to find out how
far it is from the charging station to a remote
area.

To test the settings for Follow loop out (3-2-1):

• State the value 100 % for Proportion for the

remote area to be tested and 0 % for the other
areas. Place Automower™ in the charging
station and select Test OUT (3-2-5). The
mower will now leave the charging station
directly according to the stated direction and
start mowing after the stated distance. Reset
the Proportion values when testing is finished.

IMPORTANT INFORMATION

When Test IN (3-2-4) is used, the house icon
on the display will come on and the mower
will remain in the charging station. Press the
Home button to return to operations.

3-2-4

Follow loop out

Follow loop in

Corridor width

Test IN

Test OUT

10

8

3-2-4

Follow loop out

Follow loop in

Corridor width

Test IN

Test OUT