beautypg.com

D. mantel and wall projections, 10 in. min. fireplace opening 12 in. max – Heat & Glo Fireplace Heat & Glo Gas Fireplace ESC-42ST User Manual

Page 21

background image

Heat & Glo • ESC-42ST • 2146-900 Rev. Q • 4/13

21

D. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-
ances as specifi ed. Framing or fi nishing material closer than
the minimums listed must be constructed entirely of non-
combustible materials (i.e., steel studs, concrete board, etc).
Failure to comply could cause fi re.

Combustible Mantels

Non-combustible Mantels

Combustible Mantel Legs or Wall Projections

Non-Combustible Mantel Legs or Wall Projections

Figure 5.3 Clearances to mantels or other combustibles
above

appliance

1 IN. MIN.

13 IN. MIN.

FROM OPENING

COMBUSTIBLE WALL OR

MANTEL LEG

FIREPLACE

OPENING

7 IN.

6 IN. MIN. FROM

OPENING

6 IN.
MAX.

COMBUSTIBLE

MATERIAL

Figure 5.5 Clearances to Combustible Mantel Legs or Wall

Projections.

1 IN. MIN.

13 IN. MIN.

4 IN. MAX.

FIREPLACE
OPENING

NON-COMBUSTIBLE WALL

NON-COMBUSTIBLE

MANTEL LEG

Figure 5.6 Clearances to Non-Combustible Mantel Legs or

Wall Projections.

10 IN.
MIN.

FIREPLACE
OPENING

12 IN.
MAX.

Figure 5.4 Clearances to Mantels or other Non-Combustibles
Above

Appliance

FIREPLACE
OPENING

10 IN.
MIN.

4 IN.
MAX.

12 IN.
MAX.

NON-COMBUSTIBLE
MATERIAL