beautypg.com

Heat & Glo Fireplace Heat & Glo Gas Fireplace ESC-42ST User Manual

Page 15

background image

Heat & Glo • ESC-42ST • 2146-900 Rev. Q • 4/13

15

B. Maintenance Tasks-Qualifi ed Service

Technician

The following tasks must be performed by a qualifi ed ser-
vice technician.

Glass Cleaning

(Exterior and Interior of Installed Glass)

Frequency: Seasonally

By: Qualifi ed Service Technician

Tools Needed: Protective gloves, glass cleaner, drop
cloth and a stable work surface.

WARNING! Risk of Injury! Glass installation and re-
moval should be performed only by a qualifi ed service
technician.

CAUTION! Handle fi xed glass assembly with care.
Glass is breakable.

• Avoid striking, scratching or slamming glass
• Avoid abrasive cleaners
DO NOT clean glass while it is hot

Prepare a work area large enough to accommodate fi xed

glass assembly and door frame by placing a drop cloth
on a fl at, stable surface.

Note: Fixed glass assembly and gasketing may have res-
idue that can stain carpeting or fl oor surfaces.

Remove door or decorative front from fi replace and set

aside on work surface.

• See Section 14.A for instructions to remove fi xed glass

assembly.

• Clean glass with a non-abrasive commercially available

cleaner.

- Light deposits: Use a soft cloth with soap and water

- Heavy deposits: Use commercial fireplace glass

cleaner (consult with your dealer)

• Carefully set fi xed glass assembly in place on fi replace.

Hold glass in place with one hand and secure glass
latches with the other hand.

• Reinstall door or decorative front.

Gasket Seal and Glass Assembly Inspection

Frequency: Annually

By: Qualifi ed Service Technician

Tools needed: Protective gloves, drop cloth and a stable
work surface.

• Inspect gasket seal and its condition.

• Inspect fi xed glass assembly for scratches and nicks that

can lead to breakage when exposed to heat.

• Confi rm there is no damage to glass or glass frame.

Replace as necessary.

• Verify that fi xed glass assembly is properly retained and

attachment components are intact and not damaged.
Replace as necessary.

Logs

Frequency: Annually

By: Qualifi ed Service Technician

Tools needed: Protective gloves.

• Inspect for damaged or missing logs. Replace as neces-

sary. Refer to Section 14 for log placement instructions.

• Verify correct log placement and no fl ame impingement

causing sooting. Correct as necessary.

Firebox

Frequency: Annually

By: Qualifi ed Service Technician

Tools needed: Protective gloves, sandpaper, steel wool,
cloths, mineral spirits, primer and touch-up paint.

• Inspect for paint condition, warped surfaces, corrosion

or perforation. Sand and repaint as necessary.

• Replace fi replace if fi rebox has been perforated.

Control Compartment and Firebox Top

Frequency: Annually

By: Qualifi ed Service Technician

Tools needed: Protective gloves, vacuum cleaner, dust
cloths

• Vacuum and wipe out dust, cobwebs, debris or pet hair.

Use caution when cleaning these areas. Screw tips that
have penetrated the sheet metal are sharp and should
be avoided.

• Remove all foreign objects.

• Verify unobstructed air circulation.

Burner Ignition and Operation

Frequency: Annually

By: Qualifi ed Service Technician

Tools needed: Protective gloves, vacuum cleaner, whisk
broom, fl ashlight, voltmeter, indexed drill bit set, and a
manometer.

• Verify burner is properly secured and aligned with pilot

or igniter.

• Clean off burner top, inspect for plugged ports, corrosion

or deterioration. Replace burner if necessary.

• Replace Glowing embers with new dime-size pieces.

DO NOT block ports or obstruct lighting paths. Refer to
Section 14 for proper ember placement.

• Verify batteries have been removed from battery back-

up IPI systems to prevent premature battery failure or
leaking.

• Check for smooth lighting and ignition carryover to all

ports. Verify that there is no ignition delay.

• Inspect for lifting or other fl ame problems.

• Verify air shutter setting is correct. See Section 14 for

required air shutter setting. Verify air shutter is clear of
dust and debris.