beautypg.com

Installation, Installation of the dc sparker – Hampton Direct H15-LP1 User Manual

Page 30

background image

30

Hampton

®

H15-1 Direct Vent Freestanding Gas Stove

Installation of the DC Sparker:

19) Remove the control panel by unscrewing

the 2 screws.

21) Plug up the Piezo hole with the plastic

bushing.

22) Attach the DC sparker generator

connector to the valve with a screw.

23) Remove the stove’s rear panel by unscrew-

ing the two screws.

24) Attach the ground wire to the grounding

stud.

20) First, remove the Piezo Ignition Wire

from the Piezo Ignitor. Then remove the
Piezo Ignitor from the control panel.

Before

After

12) Pull off the

pilot cap to
expose the
pilot orifi ce.

13) Unscrew the pilot orifi ce with the allen

key and replace with the LP pilot orifi ce
in the kit.

14) Remove burner orifi ce with a 1/2"

wrench and discard. Use another
wrench to hold on to the elbow behind
the orifi ce.

15) Reinstall new burner orifi ce LP stamped

#55 and tighten.

16) Reverse steps 3) to 2).

17) Attach the label "This unit has been

converted to LPG" near or on top of the
serial # decal.

18) Replace yellow "Natural Gas" label with

red "LPG" label.

11) Reassemble the black protection cap

(Fig. 6).

WARNING!

Also check that the pilot and main

burner injectors

are appropriate for the gas type.

Fig. 6

Burner Orifi ce

INSTALLATION

This manual is related to the following products: