Installation – Hampton Direct H15-LP1 User Manual
Page 21
![background image](/manuals/89334/21/background.png)
Hampton
®
H15-1 Direct Vent Freestanding Gas Stove
21
RESIDENTIAL AND MANUFACTURED HOMES / MOBILE HOMES
MINIMUM HORIZONTAL TERMINATION INSTALLATIONS
Planning Your Venting Installation
See the "Exterior Vent Terminal Locations"
section for requirements.
When planning your installation, it will be nec-
essary to select the proper length of vent pipe
for your particular requirements. Determine the
minimum clearance to combustibles from the
rear of the unit to the wall. It is also important to
note the wall thickness. Before cutting the vent
hole through the wall ensure that ALL vent and
termination clearances (Refer to the "Exterior
Vent Terminal Locations" section) will be met.
*If this is an outside corner, the minimum distance
between the vent and the outside corner is 6"
(15cm). See "F" on the diagram in the "Exterior
Vent Terminal Locations" section.
NOTE: Ensure compliance with the outside
vent terminal location before cutting hole as
both dimensions must be met.
Minimum components for a Horizontal Installation:
640-944
Horizontal Termination Kit which includes:
1
6-5/8" Dia. x 18" Black Pipe
1
4" Dia. x 18" Aluminum Vent
1
946-202
Wall Penetration Heat Shield (Wall Thimble) (2 pcs)
1 640-530/P
Riser
Vent
Terminal
1 640-545/P
Decorative
Wall
Trim
(Black)
1 948-128
Tube
Mill-Pac
Screws
380-946
Horizontal Termination Kit which includes:
1
6-5/8" Dia. x 12" Black Pipe
1
4" Dia. x 12" Aluminum Vent
1
946-202
Wall Penetration Heat Shield (Wall Thimble) (2 pcs)
1 946-523/P
AstroCap
1 640-545/P
Decorative
Wall
Trim
(Black)
1 948-128
Tube
Mill-Pac
Screws
Optional Components:
946-204
45
o
Elbow - 6-5/8" Black pipe
946-523/P AstroCap
and 4" Aluminum Vent
946-206 Vinyl Siding Standoff (AstroCap)
946-205
Vinyl Siding Shield for Riser Vent 946-506/P Vent Guard (AstroCap)
Terminal
946-208/P Vent
Guard
(Riser
Vent
Terminal)
940
Square Wall Thimble Cover*
981
Snorkel
Termination
(36")*
982
Snorkel
Termination
(14")*
942
Wall
Penetration
Heat
Shield*
* Simpson Dura-Vent Components
You will require the following components with your new Hampton
®
Direct Vent Freestanding Gas
Stove. Please review your product to make sure you have everything you need. In the event that
you are missing any part, contact your dealer. Decorative brass or chrome trim kits are available
from Simpson Dura-Vent for their wall thimbles, as well as a square wall thimble cover.
Note: These are the minimum pieces required. Other parts may be required for your par-
ticular installation.
Kit #640-944
Kit #380-946
INSTALLATION