beautypg.com

HP COMPAQ DC5100 User Manual

Page 40

background image

A-2

www.hp.com

Hardware Reference Guide

Specifications

Power Supply

115V

230V

Operating Voltage Range*

90–264 VAC

90–264 VAC

Rated Voltage Range

100–240 VAC

100–240 VAC

Rated Line Frequency

50–60 Hz

50–60 Hz

Power Output

240 W

240 W

Rated Input Current (maximum)*

5A @ 100 VAC

2.5A @ 200 VAC

Heat Dissipation

Maximum

1260 BTU/hr

318 kg-cal/hr

Typical (idle)

340 BTU/hr

86 kg-cal/hr

*This system utilizes an active power factor corrected power supply. This allows the system to
pass the CE mark requirements for use in the countries of the European Union. The active power
factor corrected power supply also has the added benefit of not requiring an input voltage
range select switch.

HP Compaq Small Form Factor (Continued)