beautypg.com

Caution, Warning – Hearth and Home Technologies Castile Insert Pellet CASTINS-CWL User Manual

Page 31

background image

R

September 1, 2008

250-7251F

Page 31

Castile Pellet Insert

12. Cleaning the Glass

Frequency: When clear view of the firepot becomes

obscure

By: Homeowner

a. Appliance must be completely cool before cleaning

glass.

b. Use a damp paper towel or any non-abrasive glass

cleaner. Wipe off with dry towel.

Handle glass assembly with care.

When cleaning glass:
• Avoid striking, scratching or

slamming glass.

• Do NOT clean glass when hot.

CAUTION

• Do NOT use abrasive cleaners.
• Use a hard water deposit glass cleaner on white film.
• Refer to maintenance instructions.

Handle glass with care.
• Inspect the gasket to ensure it is

undamaged.

• Do NOT strike, slam or scratch glass.
• Do NOT operate appliance with glass

assembly removed.

WARNING

• Do NOT operate with glass cracked, broken or

scratched.

10. Cleaning the Hopper

Frequency: Monthly or after burning 1 ton of fuel

By: Homeowner

After burning approximately 1 ton of fuel you will need to
clean the hopper to prevent sawdust build-up.

A combination of sawdust and pellets on the auger
reduces the amount of fuel supply to the firepot. This
can result in nuisance shutdowns and mis-starts.

a. The appliance must be in complete shutdown. Allow

the appliance to completely cool down.

b. Empty the hopper of any remaining pellets.

c. Vacuum the hopper and feed tube.

11. Soot and Fly Ash: Formation & Need for Removal

in Exhaust Venting System.

Frequency: Yearly or more frequently depending on

ash build-up.

By: Qualified Service Technician/Homeowner

Be sure the appliance is allowed to cool, has been unplugged
and the exhaust blower is off.

The products of combustion will contain small particles of fly
ash. The fly ash will collect in the exhaust venting system
and restrict the flow of the flue gases.

At start-up if there is incomplete combustion, or if there is a
shutdown or incorrect operation of the appliance it will lead
to some soot formation. This will collect in the exhaust vent-
ing system.

The venting system may need to be cleaned at least once a
year or more often depending upon the quality of your fuel
or if there is a lot of horizontal pipe sections. Ash will build
up more quickly in the horizontal sections.

13. Cleaning Convection Blower - Requires No

Lubrication

Frequency: Yearly or as needed

By: Qualified Service Technician

a. The appliance must be in complete shutdown and

completely cooled.

b. Remove both the left and right cast sides.

c. Use either a can of compressed air or an air com-

pressor.

d. Reach as far back as possible and spray com-

presssed air liberally from both sides at the blower.
This will remove any lint or dust build-up on the
impellers.

14. Cleaning Exhaust Blower - Requires No

Lubrication

Frequency: Yearly or as needed

By: Qualified Service Technician

Task: Contact your local dealer.

15. Door Latch Inspection

Frequency: Prior to heating season

By: Homeowner

The door latch is non-adjustable but the gasketing between
the glass and firebox should be inspected periodically to
make sure there is a good seal.

NOTE: There is no gasket on the bottom of glass.