Page 14

background image

Page 14

250-7251F

September 1, 2008

R

Castile Pellet Insert

C. Full Reline With Outside Air

Outside Air

Termination

at

Chimney Top

Outside Air
through
Rear Wall

Exit through the

Ash Clean-Out of

Masonry Chimney

12” (305mm)
min. below

12” (305mm)
min. above

NOTE; Use metal
plate around
exhaust vent pipe
and seal all edges
with non-flammable
insulation such as
fiberglass, mineral
wool or ceramic.

Do not use high
temperature caulk-
ing materials to
seal any edge to
prevent furture
serviceability.

NOTE: Check clearances carefully for this
type of installation to ensure adequate room
for outside air venting.

Check building codes prior to installation.
• Installation MUST comply with local, regional,

state and national codes and regulations.

• Consult local building, fire officials or authori-

ties having jurisdiction about restrictions,
installation inspection, and permits.

CAUTION

Figure 14.2

NOTE: In Canada, only a full reline is
allowed per ULC S-628, ORD ULC C1482.