F-801mwh-c – Hoshizaki MODULAR FLAKER F-801MAH/-C User Manual
Page 32

32
F-801MWH-C
We reserve the right to make changes in specifications and design without prior notice.
APPROXIMATE
Ambient
Water Temp. (F)
ICE PRODUCTION
Temp. (F)
PER 24 HR.
70
* 645
(293)
620
(281)
608
(276)
80
596
(270)
585
(265)
574
(260)
90
563
(255) * 550
(249)
541
(246)
lbs./day ( kg/day)
100
531
(241)
521
(236) * 485
(220)
APPROXIMATE ELECTRIC
70
* 1083
--
1082
--
1081
--
CONSUMPTION
80
1080
--
1078
--
1077
--
90
1076
--
* 1075
--
1073
--
watts
100
1072
--
1070
--
* 1068
--
APPROXIMATE WATER
70
* 276
(1046)
342
(1294)
579
(2192)
CONSUMPTION PER 24 HR.
80
287
(1086)
354
(1339)
605
(2291)
(TOTAL)
90
296
(1119) * 368
(1392)
633
(2397)
gal. / day (l/day)
100
305
(1156)
381
(1442) * 693
(2622)
EVAPORATOR OUTLET TEMP.
70
*
20
(-7)
20
(-7)
21
(-6)
°F (°C)
80
21
(-6)
21
(-6)
21
(-6)
90
21
(-6)
*
21
(-6)
21
(-6)
100
21
(-6)
21
(-6)
*
22
(-6)
HEAD PRESSURE
70
* 263
(18.5)
263
(18.5)
264
(18.6)
80
263
(18.5)
263
(18.5)
264
(18.6)
90
263
(18.5) * 263
(18.5)
264
(18.6)
PSIG (kg/cm
2
G)
100
263
(18.5)
263
(18.5) * 264
(18.6)
SUCTION PRESSURE
70
*
46
(3.2)
46
(3.3)
47
(3.3)
PSIG (kg/cm
2
G)
80
46
(3.2)
46
(3.3)
47
(3.3)
90
46
(3.2) *
46
(3.3)
47
(3.3)
100
46
(3.2)
46
(3.3) *
47
(3.3)
Note: The data without *marks should be used for reference.
50
70
90
13 gal/h (AT 90°F / WT 70°F)
Less than 7 PSIG
5155 BTU/h (AT 90°F / WT 70°F)
WATER FLOW FOR CONDENSER
PRESSURE DROP OF COOLING WATER LINE
HEAT OF REJECTION FROM CONDENSER
HEAT OF REJECTION FROM COMPRESSOR