F-801mwh – Hoshizaki MODULAR FLAKER F-801MAH/-C User Manual
Page 30

30
F-801MWH
We reserve the right to make changes in specifications and design without prior notice.
APPROXIMATE
Ambient
Water Temp. (F)
ICE PRODUCTION
Temp. (F)
PER 24 HR.
70
* 720
(327)
693
(315)
677
(307)
80
661
(300)
646
(293)
630
(286)
90
616
(279) * 605
(274)
587
(266)
lbs./day ( kg/day)
100
573
(260)
560
(254) * 520
(236)
APPROXIMATE ELECTRIC
70
* 1076
--
1076
--
1076
--
CONSUMPTION
80
1076
--
1077
--
1077
--
90
1077
--
* 1078
--
1076
--
watts
100
1074
--
1071
--
* 1069
--
APPROXIMATE WATER
70
* 306
(1158)
397
(1504)
631
(2387)
CONSUMPTION PER 24 HR.
80
318
(1205)
415
(1571)
666
(2520)
(TOTAL)
90
331
(1251) * 433
(1638)
704
(2666)
gal. / day (l/day)
100
344
(1304)
457
(1728) * 778
(2944)
EVAPORATOR OUTLET TEMP.
70
*
17
(-8)
17
(-8)
18
(-8)
°F (°C)
80
19
(-7)
19
(-7)
20
(-7)
90
20
(-7)
*
20
(-7)
20
(-7)
100
20
(-7)
20
(-7)
*
21
(-6)
HEAD PRESSURE
70
* 265
(18.6)
265
(18.6)
266
(18.7)
80
265
(18.6)
265
(18.6)
266
(18.7)
90
265
(18.6) * 265
(18.6)
266
(18.7)
PSIG (kg/cm
2
G)
100
265
(18.6)
265
(18.6) * 266
(18.7)
SUCTION PRESSURE
70
*
42
(3.0)
43
(3.0)
44
(3.1)
PSIG (kg/cm
2
G)
80
42
(3.0)
43
(3.0)
44
(3.1)
90
42
(3.0) *
43
(3.0)
44
(3.1)
100
42
(3.0)
43
(3.0) *
44
(3.1)
Note: The data without *marks should be used for reference.
HEAT OF REJECTION FROM COMPRESSOR
1050 BTU/h (AT 90°F / WT 70°F)
WATER FLOW FOR CONDENSER
15 gal/h (AT 90°F / WT 70°F)
PRESSURE DROP OF COOLING WATER LINE
Less than 7 PSIG
HEAT OF REJECTION FROM CONDENSER
50
70
90
5155 BTU/h (AT 90°F / WT 70°F)