reads from one. If a read error occurs, the system fails over to the redundant memory
board. At that point the memory board containing the failed DIMMs can be hot replaced.
Once the failed DIMMs are replaced and the memory board re-installed into the server, the
system goes back to full mirrored status. All this occurs without bringing the server down.
Hot Plug RAID Memory
Hot Plug RAID Memory (RAID Memory) provides a similar level of memory protection as
Mirrored Memory but obtains this protection using less total memory. For example, in a
RAID Memory configuration, 25% of the installed memory is not available to the operating
system. In a Mirrored Memory configuration, however, 50% of the installed memory is not
available to the operating system. RAID Memory protects the server against uncorrectable
memory errors that would otherwise result in a server failure.
NOTE: All Advanced Memory Protection modes require the use of additional memory cards.
All HP ProLiant ML570 G3 servers ship standard with a single memory board. Additional
memory boards are optional (P/N 348107-B21).
NOTE: All Advanced Memory Protection modes are user configurable through the ROM-
Based Setup Utility (RBSU) and viewable through Systems Insight Manager and the
Integrated Management Log (IML.).
Remote Management
Integrated Lights Out (iLO) Standard Management:
Virtual Text Remote Console
Virtual Power Button Control
Dedicated & shared LAN Connectivity
Browser and command line access
Automatic IP Configuration via DHCP/DNS/WINS
Industry Standard 128-bit Secure Sockets Layer (SSL) and Secure Shell Security
IML and iLO Event Logging
Support for 12 user accounts with customizable access privilege
Integrated Lights Out Advanced Pack (optional) Remote Graphical Console:
Microsoft Remote Desktop for Administrators integration
Virtual media (floppy, CD, USB key, floppy images and ISO images)
User access management via Directory Services
Two-factor authentication
Intelligent
Manageability
HP Systems Insight Manager
SmartStart
Redundant ROM
Remote Flash ROM
Management Agent
Integrated Management Log
Automatic Server Recovery (ASR)
Dynamic Sector Repairing (with Smart Array Controllers)
Drive Parameter Tracking (with Smart Array Controllers)
Pre-Failure Warranty (covers processors, SCSI/SAS hard drives and memory)