beautypg.com

1. selecting equipment, 2. grounding generator to truck or trailer frame – Hobart Welding Products CHAMPION 4500 OM-4418 User Manual

Page 33

background image

OM-4418 Page 29

SECTION 11 − GENERATOR POWER GUIDELINES

.

The views in this section are intended to be representative of all engine-driven welding generators. Your unit may differ from those shown.

11-1. Selecting Equipment

gen_pwr 2007−04 − Ref. ST-159 730 / ST-800 577

1

Generator Power Receptacles

− Neutral Bonded To Frame

2

3-Prong Plug From Case

Grounded Equipment

3

2-Prong Plug From Double

Insulated Equipment

.

Be sure equipment has double
insulated symbol and/or word-
ing on it.

Do not use 2-prong plug un-
less equipment is double in-
sulated.

OR

2

3

1

Always ground generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.

Also see AWS Safety &
Health Fact Sheet No. 29,
Grounding of Portable And
Vehicle Mounted Welding
Generators.

1

Equipment Grounding

Terminal (On Front Panel)

2

Grounding Cable (Not

Supplied)

3

Metal Vehicle Frame

Connect cable from equipment

ground terminal to metal vehicle

frame. Use #10 A WG or larger

insulated copper wire.

.

Electrically bond generator
frame to vehicle frame by met-
al-to-metal contact.

Bed liners, shipping skids,
and some running gear insu-
late the welding generator
from the vehicle frame. Al-
ways connect a ground wire
from the generator equip-
ment grounding terminal to
bare metal on the vehicle
frame as shown.

If unit does not have GFCI re-
ceptacles, use GFCI-pro-
tected extension cord.

11-2. Grounding Generator To Truck Or Trailer Frame

S-0854

GND/PE

3

1

2

This manual is related to the following products: